  "dataset_name": "Residential Radon Mitigation Diagram Library",
  "version": "1.1",
  "verified_date": "2026-07-24",
  "records": [
    {
      "record_id": "RMSD-001",
      "diagram_id": "D01",
      "diagram_title": "Active sub-slab depressurization — interior route",
      "system_family": "Active soil depressurization",
      "foundation_type": "Basement or slab-on-grade",
      "collection_interface": "Suction point or pit beneath slab",
      "fan_present": "Yes",
      "fan_location_shown": "Unconditioned attic/garage zone; exact placement governed by current standard and jurisdiction",
      "vent_route": "Interior vertical route to outdoor discharge",
      "monitoring_component": "U-tube pressure indicator plus system warning device; separate radon test device shown",
      "component_ids": "C01|C02|C03|C07|C08|C09|C10|C11|C12|C13|C14|C17|C18",
      "primary_source_org": "U.S. EPA; Iowa HHS / Iowa Administrative Rules",
      "primary_source_title": "Consumer’s Guide to Radon Reduction (2025); Iowa Administrative Code 641—Chapter 44",
      "source_publication_or_effective_date": "EPA guide 2025; Iowa rule effective 2026-07-01",
      "source_url": "https://www.epa.gov/sites/default/files/2016-12/documents/2016_consumers_guide_to_radon_reduction.pdf | https://rules.iowa.gov/Notice/Details/0290D",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "Paid professional mitigation generally requires Iowa credentialing; current rule incorporates ANSI/AARST SGM-SF-2023 as amended through 2025-08-01.",
      "limitations": "Conceptual, not to scale. Does not specify pipe diameter, fan model, electrical design, exhaust clearances, or suction diagnostics."
    },
    {
      "record_id": "RMSD-002",
      "diagram_id": "D02",
      "diagram_title": "Active sub-slab depressurization — exterior route",
      "system_family": "Active soil depressurization",
      "foundation_type": "Basement or slab-on-grade",
      "collection_interface": "Interior or exterior sub-slab suction point",
      "fan_present": "Yes",
      "fan_location_shown": "Exterior, with outdoor-rated installation concept only",
      "vent_route": "Foundation penetration to exterior riser and outdoor discharge",
      "monitoring_component": "Indoor-visible pressure indicator; separate radon test device",
      "component_ids": "C01|C02|C03|C07|C08|C09|C10|C11|C12|C13|C14|C18",
      "primary_source_org": "U.S. EPA; Iowa HHS / Iowa Administrative Rules",
      "primary_source_title": "Consumer’s Guide to Radon Reduction (2025); Iowa Administrative Code 641—Chapter 44",
      "source_publication_or_effective_date": "EPA guide 2025; Iowa rule effective 2026-07-01",
      "source_url": "https://www.epa.gov/sites/default/files/2016-12/documents/2016_consumers_guide_to_radon_reduction.pdf | https://rules.iowa.gov/Notice/Details/0290D",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "Use the Iowa legal overlay only for Iowa installations; national figure remains schematic.",
      "limitations": "No universal cold-weather insulation, slope, diameter, sound, or clearance specifications are asserted."
    },
    {
      "record_id": "RMSD-003",
      "diagram_id": "D03",
      "diagram_title": "Drain-tile suction system",
      "system_family": "Active soil depressurization using drain tile",
      "foundation_type": "Basement or slab with perimeter drainage path",
      "collection_interface": "Existing drain tile or perforated collection loop",
      "fan_present": "Yes",
      "fan_location_shown": "Generic unconditioned/exterior zone",
      "vent_route": "Drain-tile connection to vent riser and discharge",
      "monitoring_component": "Pressure indicator and separate radon test device",
      "component_ids": "C01|C04|C05|C07|C08|C09|C10|C11|C13|C14|C18",
      "primary_source_org": "U.S. EPA",
      "primary_source_title": "Consumer’s Guide to Radon Reduction (2025)",
      "source_publication_or_effective_date": "2025",
      "source_url": "https://www.epa.gov/sites/default/files/2016-12/documents/2016_consumers_guide_to_radon_reduction.pdf",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "Iowa credentialing and SGM-SF overlay applies to compensated existing-home work.",
      "limitations": "A drain-tile path is shown conceptually; the figure cannot establish whether a real drainage network communicates adequately."
    },
    {
      "record_id": "RMSD-004",
      "diagram_id": "D04",
      "diagram_title": "Sump-hole suction system",
      "system_family": "Active soil depressurization using sump opening",
      "foundation_type": "Basement or slab with sump",
      "collection_interface": "Sealed, serviceable sump opening connected to sub-slab zone",
      "fan_present": "Yes",
      "fan_location_shown": "Generic unconditioned/exterior zone",
      "vent_route": "Sump connection to vent riser and discharge",
      "monitoring_component": "Pressure indicator and separate radon test device",
      "component_ids": "C01|C02|C05|C07|C08|C09|C10|C11|C13|C14|C18",
      "primary_source_org": "U.S. EPA",
      "primary_source_title": "Consumer’s Guide to Radon Reduction (2025)",
      "source_publication_or_effective_date": "2025",
      "source_url": "https://www.epa.gov/sites/default/files/2016-12/documents/2016_consumers_guide_to_radon_reduction.pdf",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "The schematic does not replace Iowa-required diagnostic design or post-mitigation testing.",
      "limitations": "Does not prescribe a cover product, drainage connection, pump service access, or flood-control design."
    },
    {
      "record_id": "RMSD-005",
      "diagram_id": "D05",
      "diagram_title": "Crawlspace submembrane depressurization",
      "system_family": "Active submembrane soil depressurization",
      "foundation_type": "Crawlspace",
      "collection_interface": "Suction beneath sealed soil-gas-retarder membrane",
      "fan_present": "Yes",
      "fan_location_shown": "Generic unconditioned/exterior zone",
      "vent_route": "Submembrane connection to vent riser and discharge",
      "monitoring_component": "Pressure/system indicator and separate radon test device in occupied area",
      "component_ids": "C01|C06|C07|C08|C09|C10|C11|C13|C14|C18",
      "primary_source_org": "U.S. EPA",
      "primary_source_title": "Consumer’s Guide to Radon Reduction (2025)",
      "source_publication_or_effective_date": "2025",
      "source_url": "https://www.epa.gov/sites/default/files/2016-12/documents/2016_consumers_guide_to_radon_reduction.pdf",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "Current standard and jurisdiction govern membrane, seams, service openings, fan, and discharge details.",
      "limitations": "No membrane thickness, seam method, anchorage, drainage, or structural requirements are asserted."
    },
    {
      "record_id": "RMSD-006",
      "diagram_id": "D06",
      "diagram_title": "Block-wall suction combined with sub-slab suction",
      "system_family": "Combined active soil and hollow-wall depressurization",
      "foundation_type": "Basement with hollow block foundation wall",
      "collection_interface": "Hollow block-wall path plus sub-slab suction zone",
      "fan_present": "Yes",
      "fan_location_shown": "Generic unconditioned/exterior zone",
      "vent_route": "Joined collection branches to riser and discharge",
      "monitoring_component": "Pressure indicator and separate radon test device",
      "component_ids": "C01|C02|C03|C07|C08|C09|C10|C11|C13|C14|C16|C18",
      "primary_source_org": "U.S. EPA",
      "primary_source_title": "Consumer’s Guide to Radon Reduction (2025)",
      "source_publication_or_effective_date": "2025",
      "source_url": "https://www.epa.gov/sites/default/files/2016-12/documents/2016_consumers_guide_to_radon_reduction.pdf",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "The combination is an illustrated system family, not a recommendation for every block-wall home.",
      "limitations": "Does not show site-specific block-wall openings, firestopping, structural work, or pressure-field diagnostics."
    },
    {
      "record_id": "RMSD-007",
      "diagram_id": "D07",
      "diagram_title": "Mixed-foundation and multiple-zone system",
      "system_family": "Combined active soil depressurization",
      "foundation_type": "Basement plus slab-on-grade and/or crawlspace",
      "collection_interface": "Two or more independently identified foundation zones",
      "fan_present": "Yes, shown as one conceptual interconnected system; actual design may differ",
      "fan_location_shown": "Generic unconditioned/exterior zone",
      "vent_route": "Multiple collection branches to one conceptual riser/discharge",
      "monitoring_component": "System indicators plus separate radon testing",
      "component_ids": "C01|C02|C03|C06|C07|C08|C09|C10|C11|C13|C14|C15|C18",
      "primary_source_org": "U.S. EPA; Iowa HHS / Iowa Administrative Rules",
      "primary_source_title": "Consumer’s Guide to Radon Reduction (2025); Iowa Administrative Code 641—Chapter 44",
      "source_publication_or_effective_date": "EPA guide 2025; Iowa rule effective 2026-07-01",
      "source_url": "https://www.epa.gov/sites/default/files/2016-12/documents/2016_consumers_guide_to_radon_reduction.pdf | https://rules.iowa.gov/Notice/Details/0290D",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "Iowa’s fee rule recognizes interconnected systems may contain one or more fans, suction points, and exhausts; this drawing does not determine fee treatment.",
      "limitations": "The number of suction points, fans, branches, and zones must be determined for the building; one fan or one riser is not claimed sufficient."
    },
    {
      "record_id": "RMSD-008",
      "diagram_id": "D08",
      "diagram_title": "Passive radon system in new construction",
      "system_family": "Passive sub-slab system / radon-resistant new construction",
      "foundation_type": "New one- or two-family dwelling",
      "collection_interface": "Prepared sub-slab collection layer or suction point",
      "fan_present": "No",
      "fan_location_shown": "Fan-ready location may be identified but no fan is active",
      "vent_route": "Vertical route through conditioned space to roof discharge; Iowa rule definition specifies 12 inches above roof",
      "monitoring_component": "No active-system fan monitor shown; radon testing remains separate",
      "component_ids": "C01|C02|C03|C07|C08|C10|C14|C17|C18",
      "primary_source_org": "Iowa General Assembly; Iowa HHS; ANSI/AARST",
      "primary_source_title": "Iowa Acts Ch. 1124 (HF 2297); Iowa Administrative Code 641—Chapter 44; CCAH-2020-0523 listing",
      "source_publication_or_effective_date": "Act approved 2026-05-19; Iowa code edition checked 2026-07-08; CCAH rev. 2023",
      "source_url": "https://www.legis.iowa.gov/docs/publications/iactc/91.2/CH1124.pdf | https://www.legis.iowa.gov/docs/iac/chapter/07-08-2026.481.301.pdf | https://standards.aarst.org/",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "Iowa Acts Ch. 1124 directs adoption of a 2021 IRC Appendix AF passive method for construction commenced after adoption. The published 2026-07-08 Chapter 301 still deletes appendices AA–CH; confirm the current code for project-specific status.",
      "limitations": "National plate must not present Iowa’s 12-inch definition or the statutory adoption direction as a universal or project-specific code conclusion."
    },
    {
      "record_id": "RMSD-009",
      "diagram_id": "D09",
      "diagram_title": "Passive-to-active conversion",
      "system_family": "Activation of passive system",
      "foundation_type": "Existing fan-ready passive system",
      "collection_interface": "Existing passive collection layer and vent route",
      "fan_present": "Yes after conversion",
      "fan_location_shown": "Conceptual code-compliant unconditioned/exterior location",
      "vent_route": "Existing passive riser activated by added in-line fan",
      "monitoring_component": "Active-system pressure/warning indication plus separate radon test",
      "component_ids": "C01|C02|C03|C07|C08|C09|C10|C11|C12|C13|C14|C17|C18",
      "primary_source_org": "Iowa HHS / Iowa Administrative Rules; ANSI/AARST",
      "primary_source_title": "Iowa Administrative Code 641—Chapter 44; CCAH-2020-0523 listing",
      "source_publication_or_effective_date": "Iowa rule effective 2026-07-01; CCAH rev. 2023",
      "source_url": "https://rules.iowa.gov/Notice/Details/0290D | https://standards.aarst.org/",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "In Iowa, conversion of a passive system to an active system must be performed by a person credentialed under Chapter 44.",
      "limitations": "The plate does not assert that every passive pipe is suitable for activation without evaluation."
    },
    {
      "record_id": "RMSD-010",
      "diagram_id": "D10",
      "diagram_title": "Manometer versus radon test — what each device shows",
      "system_family": "Monitoring and verification detail",
      "foundation_type": "Any active system; passive comparison included",
      "collection_interface": "Not applicable",
      "fan_present": "Active-system example: yes; passive-system example: no",
      "fan_location_shown": "Not the focus",
      "vent_route": "Small pipe segment detail only",
      "monitoring_component": "U-tube manometer indicates pressure/flow condition; radon test measures radon concentration",
      "component_ids": "C08|C09|C11|C13|C18",
      "primary_source_org": "Michigan EGLE; U.S. EPA",
      "primary_source_title": "Even homes with radon mitigation systems should test every two years (2025); Consumer’s Guide to Radon Reduction (2025)",
      "source_publication_or_effective_date": "2025-01-29; EPA guide 2025",
      "source_url": "https://www.michigan.gov/egle/newsroom/mi-environment/2025/01/29/test-for-radon | https://www.epa.gov/sites/default/files/2016-12/documents/2016_consumers_guide_to_radon_reduction.pdf",
      "verification_date": "2026-07-24",
      "verification_tier": "★",
      "iowa_rule_note": "Iowa post-mitigation testing requirements are separate from system pressure indication.",
      "limitations": "No universal “correct” manometer number is published; the normal baseline is system-specific."
    }
  ]
}